Leave Your Message
AI Helps Write
Dual Workstation Glove Box for Battery Lab - China Suppliers and Factory with Enhanced HF Absorption Technology
Hot Products

Dual Workstation Glove Box for Battery Lab - China Suppliers and Factory with Enhanced HF Absorption Technology

This advanced battery glove box from China suppliers is designed with an enhanced organic solvent adsorption device that effectively captures HF. By minimizing electrolyte damage to its components, this factory-engineered solution ensures reliable performance and longevity. Optimize your operations with this essential equipment, ideal for high-precision environments
  • Brand WS
  • Original Dongguan, China
  • MOQ 1 PC
  • Lead time 2 Months
  • Certified: CE, UL

Equipment Characteristics

The glove box represents a state-of-the-art closed-circulation system meticulously designed to uphold a pristine environment crucial for scientific research and battery manufacturing.

Environmental Control

The glove box efficiently removes water and oxygen molecules, maintaining an inert atmosphere with oxygen (O2) and water (H2O) levels kept below 1 part per million (ppm). This controlled environment is essential for preventing oxidation and contamination, ensuring optimal conditions for battery research and development.

Applications in Battery Manufacturing

Tailored for lithium and sodium battery manufacturing, the glove box plays a pivotal role in creating a contamination-free environment. This environment is critical for producing high-quality batteries with enhanced performance and extended lifespan. By eliminating impurities, the glove box safeguards sensitive battery components during fabrication, contributing to consistent product quality and reliability.

Role in Research and Development

In various battery research and development endeavors, including solid-state battery research, the glove box is indispensable. It eliminates contaminants and establishes an inert atmosphere necessary for conducting precise experiments and gathering reliable data. This controlled environment enables researchers to accurately assess battery performance under controlled conditions, facilitating advancements in battery technology.

Economic and Practical Solution

As an economical solution tailored for scientific purposes, the glove box offers cost-effective benefits in maintaining controlled environments. Its design ensures ease of operation and maintenance, optimizing workflow efficiency in research laboratories and pilot-scale battery production facilities.

Innovation and Quality Assurance

By maintaining stringent environmental controls, the glove box supports innovation in battery manufacturing. It fosters continuous improvements in battery design, performance, and safety by providing a stable environment for testing and development. Quality assurance measures implemented within the glove box environment contribute to the production of reliable batteries that meet industry standards and consumer expectations.

In Summary

The glove box stands as a cornerstone in battery research and manufacturing, providing a controlled environment essential for producing high-performance batteries and advancing battery technology. Its capability to eliminate contaminants and maintain inert atmospheres underscores its significance in achieving breakthroughs in energy storage solutions and solid-state battery development.

Specification of Equipment

Products Dual Workstation Glove Box 4-station Glove Box
Model WS-DCF200SD-A -
Operation type Manual Manual
Station 2 4
Temperature RT°C RT°C
Environment Humidity is 30~90RH Humidity is 30~90RH
Overall size L2200*W900*H1900mm L4400*W900*H1900mm
Inner size L1200*W750*H900mm L1200*W750*H900mm
Weight 250KG 460kg

Frequently Asked Questions (FAQ)

What is the primary function of the glove box in battery manufacturing?
The glove box provides a closed-circulation system that eliminates moisture and oxygen, creating a contamination-free inert atmosphere necessary for protecting sensitive battery materials during fabrication.
How low can the water and oxygen levels be maintained inside the system?
The system maintains strict environmental control, keeping both water (H2O) and oxygen (O2) levels below 1 part per million (ppm) to effectively prevent oxidation.
What are the physical dimensions of the WS-DCF200SD-A model?
The WS-DCF200SD-A is a 2-station model with an overall size of L2200*W900*H1900mm and an inner working space of L1200*W750*H900mm.
How does the 4-station model differ from the 2-station model?
The 4-station model offers double the operation points for multiple users, with an expanded overall length of L4400mm compared to L2200mm for the 2-station model, and weighs 460kg.
Is this equipment suitable for solid-state battery research?
Yes, the glove box is highly critical and widely used for solid-state battery research, where eliminating ambient moisture and contaminants is essential to guarantee precise experimental results.